Insulation Between, and Insulated Plasterboard Fixed to,. Timber Framework on Solid Brick Wall. Damp proof course. Kingspan Kooltherm®. K12 Framing Board. Total R–values for various thicknesses of Kingspan Kooltherm®. K12 Framing Board and different wall types. Product Thickness. Heat flow in. Heat flow out. Kooltherm K12 Framing Board, insulation for timber and steel framing systems. Kingspan Kooltherm K Framing Board is a premium performance insulation.

Author: Zolokree Yokora
Country: Kenya
Language: English (Spanish)
Genre: Relationship
Published (Last): 22 January 2015
Pages: 295
PDF File Size: 13.20 Mb
ePub File Size: 10.58 Mb
ISBN: 435-5-37051-685-8
Downloads: 58520
Price: Free* [*Free Regsitration Required]
Uploader: Yozshugal

Fix Kingspan Kooltherm K12 Framing Board to the external surface of the frame structure ensuring vertical board joints coincide with a vertical member.

Cold Bridging When installed between timber studwork, the effects of cold bridging must be taken into account.

However, it is recommended that any spills be cleaned off fully before the boards are installed. External Masonry — Timber Frame Wall with Insulating Sheathing K12 framing board should be fixed to the external surface of the timber frame structure outside of any OSB or plywood sheathing and restrained using temporary fixing in the form of large headed galvanised clout nails prior to being tied into the masonry leaf with an appropriate timber frame wall tie.

The Kingspan Insulation Technical Service Department see rear cover can provide this service Surface Condensation Surface condensation can be controlled by the selection of the correct thickness of insulation, the heating and ventilation system being designed with condensation in mind, and subsequently the combination of heating and ventilation being used correctly.

However, it is recommended that any spills be cleaned off fully before the boards are installed. Kingspan Kooltherm K12 Framing Board is a premium performance rigid thermoset phenolic insulation faced on both sides with a low emissivity composite foil.

  CHECKSUM MD5 MISMATCH FOR GNUPLOT PDF

Kooltherm K12 Framing Board

The outer leaf of masonry may be constructed in the conventional manner using appropriate wall ties to restrain the two wall skins together. Ask for the conditions. Kingspan Kooltherm K12 Framing Board should be described in specifications as: To find out more about the cookies we use, or to change your cookie preferences i. When utilising K12 between studwork, the plasterboard lining should be of the vapour check type or a separate polythene vapour control layer used.

If, however, temporary outdoor storage cannot be avoided then the boards should be stacked flat on a level base, clear kingspaj the ground, and completely protected from inclement weather through use of a kinngspan sheet or weatherproof tarpaulin. The Kooltherm K12 frame plate has a low Lambda value from 0. Please contact the Kingspan Insulation Technical Service Department see contact information below for further information.

The kingsapn core is not resistant to some solvent—based adhesive systems, particularly those containing methyl ethyl ketone. The Selwyn Aquatic Kinfspan in Rolleston provides an aquatic experience that can be enjoyed all year round. Pricing and Where to Buy.

System R-values Click on the specific application types below to view their System R-values. Round Thermahood Downlight Cover.

Iingspan teams are dedicated to helping you make process as easy as possible and ensure you get the right materials for your needs. Presently there are no availability restrictions, apart from manufacturing lead-times and minimum quantity order levels on the 25mm, 40mm, 75mm, 80mm, 90mm, mm, mm, mm, mm and mm boards. Contact us to find your local representative.

Provide your abode perfect insulation and maintain the inside environment warm and cozy in winters and moderate temperature in summers. Its durability depends on the supporting structure and the conditions of its use. Kooltherm K12 Framing Board. Dwarf Wall — Insulation Between Studs To restrain insulation boards from moving within the timber stud cavity, side nail battens to the stud to provide a ‘stop’.

  BORISLAV PEKIC 1999 PDF

Wall Ties — Steel Frame Wall Advice should be sought from the appropriate steel frame manufacturer for recommendations of a suitable wall tie specification. Do you need help and advice on your project?

Determination of compression behaviour. This reflective, low emissivity surface can effectively double the thermal resistance of the cavity in which the board is placed.

Kingspan Kooltherm K12 80mm 2400mm x 1200mm (Pack / 4 sheets per pack)

Share Twitter Facebook LinkedIn. Adhesives containing such solvents should not be used in association with this product.

Send Us An Enquiry. Please note that the reflective surfaces on this product are designed to enhance their thermal performance. Delivery throughout The Netherlands. Foil facings are conductive to electricity – avoid contact with un-insulated electrical cables and fittings. Damaged boards or boards that have been in contact with harsh solvents or acids should not be used. Pack Kooltherm k12 80 mm thick High-quality insulation for parapets, interior walls or post-insulation of pitched roofs.

Our phone lines are open Monday – Friday from 8: Click Add to Cart Button.

Fill all gaps with expanding urethane sealant. This should coincide with board thickness, allowing the K12FramingBoardtofinishflushwith the outside surface of the timbers.

Buy Kingspan K12 80mm Insulation Board | Kooltherm K12 80mm

The problem is avoided when insulating outside or inside the studwork. Request a quote on large quantities. To find out more about the cookies we use, or to change your cookie preferences i.